Measuring ranges

Liquids¹: 0,5 – 100.000 l/h
Gases:²: 15 - 3.000.000 l/h

Measuring accuracy
acc. to VDI/VDE 3513-2
( qG=50 % )

Liquids: 1,6
Gases: 2,0

Pressure limits

max. 400 bar

Temperature limits

-40 °C to +350 °C

Medium-affected parts

Stainless steel, PTFE, Hastelloy

Float materials

Stainless steel, PTFE, Hastelloy

Flow direction

vertically upwards

Process connections

DIN ISO 228: G ¼ - G 3
ANSI B.1.20.1: NPT ¼“ - NPT 3“
DIN EN 1092-1: DN 15 – DN 150
ANSI B 16.5: ½“ – 6“

Options

Magnetic spring contact(s)
Inductive contact(s)
Analog current output 4-20mA
Float dampingHART®-protocol
PROFIBUS® PA-interface
ATEX version

¹ Standard measurement range for liquids (ρ = 1 kg/l, viscosity 1 mPa.s)

² Standard measurement range for gases (Pe = 0 bar pressure, T = 0 °C, ρ = 1,293 kg/m³, v = 0,0181 mPa.s)